Troubleshooting
6. Check for the following “normal power up sequence” to be sure that your system
meets the minimal hardware requirements and is powered up under normal
operation:
a. The front panel Power On/Standby LED turns green.
b. The fans start up.
c. The server ROM initializes the server in the following sequence:
Video initialization—The HP initialization screen is displayed.
— Processor initialization
— Memory test
— Memory initialization
— Diskette drive
SCSI devices (if applicable)
ATA devices (if applicable)
— Option ROM
d. The operating system loads to complete the boot process.
If the problem persists, continue with the following section, “Diagnosis Steps.”