LED Indicators, Switches, and Jumpers
Resetting System Configuration Settings
It may be necessary at some time to clear and reset system configuration settings.
When the system configuration switch position 6 is set to the on position, the system
is prepared to erase all system configuration settings from both CMOS and NVRAM.
To reset the system configuration settings:
IMPORTANT: Clearing nonvolatile RAM (NVRAM) deletes your configuration information.
Refer to Chapter 5 for complete instructions on configuring the server.
1. Power down the server.
2. Set the system configuration switch position 6 to the on position.
3. Power up the server.
All configuration settings are now erased and all system operations halt.
4. Power down the server.
5. Reset the position 6 switch to the default off position.
6. Power up the server.
7. Reset all system configuration settings.
Refer to Chapter 5, “Server Configuration and Utilities,” or the ROM-Based Setup
Utility User Guide found on the server documentation CD, for more information on
RBSU.
E-12 HP ProLiant ML350 Generation 3 Server Setup and Installation Guide