14 CHAPTER 1: INTRODUCING THE SERVER LOAD BALANCER
LEDs Table 5 lists LEDs visible on the front of the Server Load Balancer, and how
to read their status according to color.
Ta b l e 5 LED Behavior
LED Color Indicates
Power/Self Test LED
Yellow The Server Load Balancer has failed its Power On Self
Test (POST) or a failure is detected in the runtime.
Yellow flashing The Server Load Balancer is running POST.
Off No fault has been detected.
Power LED
Green The Server Load Balancer is receiving power.
Green flashing The Server Load Balancer is receiving power and
downloading new operating software.
Off The Server Load Balancer is not receiving power.
10/100BASE-T Port Status LEDs
Packet Yellow Packets are being transmitted/received on the port.
Off No packets are being transmitted/received on the port.
Status Green A link is present and the port is enabled.
Green flashing The port is disabled.
Off No link is present.
1000BASE-SX Port Status LEDs
Packet Yellow Packets are being transmitted/received on the port.
Off No packets are being transmitted/received on the port.
Status Green A high speed (1000 Mbps) link is present, and the port
is enabled.
Green flashing A high speed (1000 Mbps) port is disabled.
Off No link is present.