HP SuperStack 3 Load Balancer Appliance Manual de usuario Pagina 83

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 99
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 82
B
TECHNICAL SPECIFICATIONS AND
PIN-OUTS
Server Load
Balancer
Specifications
The following table lists the technical specifications for the Server Load
Balancer and the Server Load Balancer Plus:
Physical Dimensions Height: 65.8 mm (2.59 in.) x Width: 440 mm (17.3 in.) x Depth: 368.4 mm
(14.5 in.). Weight: 6.6 Kg (14.55 lbs)
Environmental Requirements
Operating Temperature 0 ° to 40 °C (32 ° to 104 °F)
Storage Temperature 40 ° to +70 °C (8 ° to 158 °F)
Operating Humidity 1095% relative humidity, non-condensing
Standards EN60068 to 3Com schedule (Package testing: paras 2.1, 2.2, 2.30, and 2.32.
Operational testing: paras 2.1, 2.2, 2.30 and 2.13).
Safety
Agency Certifications UL 1950, EN60950, CSA 22.2 No. 950, IEC 60950, IEC 825-1, EN 60825-1
EMC
Emissions CISPRR 22 Class A, EN55022 (1998) Class A, FCC Part 15 Subpart B Class A,
ICES-003 Class A, VCCI Class A, AS/NZS 3548 Class A, CNS 13438 Class A,
EN61000-3-2
Immunity EN 55024 (1998)
Heat Dissipation 250 watts maximum (850 BTU/hour maximum)
Power Supply
AC Line Frequency 50/60 Hz
Input Voltage Options 100240 VAC
Current Rating 3 A (amps ) (maximum)