Hp 3PAR Operating System Software Manual de usuario Pagina 61

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 289
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 60
where:
<target_name>—Name of the remote-copy target system (SystemC).
IP—Specifies an IP link.
<N:S:P>:<IP_addr>—Node on the backup system (SystemB) that contains the IP
connections to the target system, expressed as node:slot:port, and the IP address for the
target system (SystemC) (2:4:1:10.100.33.63 and 3:4:1:10.101.33.63).
4. To start HP 3PAR Remote Copy on the other backup system (SystemC), issue the following
command:
# startrcopy
5. Define a target system (for example, the primary system, SystemA) for the second backup
system. On that system (SystemC), issue the following command:
For RCFC
# creatercopytarget <target_name> FC <node_WWN> <N:S:P>:<WWN> <N:S:P>:<WWN>
where:
<target_name>—Name of the remote-copy target system (SystemB)
FC—Specifies an FC link
<node_WWN>—WWN of the target node (SystemA)
<N:S:P>:<WWN>—FC adapter port on the backup system (SystemC), expressed as
node:slot:port, and the WWN of the peer port of the target system (SystemA)
For RCIP
# creatercopytarget <target_name> IP <N:S:P>:<IP_addr> <N:S:P>:<IP_addr>
where:
<target_name>—Name of the remote-copy target system (SystemA).
IP—Specifies an IP link.
<N:S:P>:<IP_addr>—Node on the backup system (SystemC) that contains the IP
connections to the target system, expressed as node:slot:port, and the IP address for the
target system (SystemA) (2:4:1:10.100.33.96 and 3:4:1:10.101.33.96).
Setting Up the Backup Systems for SLD Remote Copy 61
Vista de pagina 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 288 289

Comentarios a estos manuales

Sin comentarios