Tabl e 9 OCP compo n e n ts for a s tandalone library or the primary cab inet of a Cross
Linked system
Screen
Displays Options to view or select
Home
Status
Library Name, Date, Model Number, IP Address,
Configured Slots, Configured Drives, P orts, Partitioned
(primary only), Library State
Menu
Menu items
Library, Cabinet, Health Status, Partitions (primary only),
Setup, Service, Event Log
Ports
Load Ports
Open Left Load Port, Open Right Load Port, Open Both
Load P orts
Ops Operations
Library (primary only)
• Online
• Inventory Reboot
• Offline
Cabinet
• Online
• Offline
• Inventory
• Reboot (standalone only)
• Details
CLM (primary only)
• Details
• Reboot
Move Media
• Source Type
• Source Position
• Destination Type
• Destination P osition
• Perform Move Now
Drive All
• Reset
• Unthread
• On
• Off
Drive #
• Details
• Reset
• Unthread
• On
• Off
Diags
Diagnostics
Ro
botics Self Test, I ndividual Axis Self Test, Robotics to
H
ome Position, Calibrate Cabinet, Read Cabinet Serial
N
umbers, Read Cabinet IEEE Id, Read Cabinet Type, CLM
S
elf Test (primary only), CLM to Home Position (primary
only), Sequential Slot Test, Sequential Drive Test, Random
Test, Random Slot Test, Random Slot to Drive Test, Element
to Element Test
Table 10 provides a list of the OCP functionality available from the Home screen of a standalone library
or the Primary cabinet of a Cross Linked library (see Figure 31).