Hp StorageWorks 1510i Modular Smart Array Manual de usuario Pagina 109

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 154
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 108
show disks
Description Lists the disks and information pertaining to them. The following information
is displayed:
•Disknumber
Enclosure box and bay number
Enclosure bus number and ID
•Disksize
•Diskspeed
•LUNinwhichthediskisused
Syntax
show disks
Operands None
Example
CLI> show disks
Disk List: (box,bay) (B:T:L) Size Speed Units
Enclosure 1: SCSI (0:06:00) PROLIANT 4LEE CP20
Disk101 (1,01) (0:00:00) 146.8GB 160 MB/s 0, 1, 2
Disk102 (1,02) (0:01:00) 146.8GB 160 MB/s 0, 1, 2
Disk103 (1,03) (0:02:00) 146.8GB 160 MB/s 0, 1, 2
Disk104 (1,04) (0:03:00) 146.8GB 160 MB/s 0, 1, 2
Disk105 (1,05) (0:04:00) 146.8GB 160 MB/s 0, 1, 2
Disk106 (1,06) (0:05:00) 146.8GB 160 MB/s 0, 1, 2
Disk107 (1,07) (0:08:00) 146.8GB 160 MB/s 0, 1, 2
Disk108 (1,08) (0:09:00) 146.8GB 160 MB/s 0, 1, 2
Disk109 (1,09) (0:10:00) 146.8GB 160 MB/s 0, 1, 2
Disk110 (1,10) (0:11:00) 146.8GB 160 MB/s 0, 1, 2
Disk111 (1,11) (0:12:00) 146.8GB 160 MB/s 0, 1, 2
Disk112 (1,12) (0:13:00) 146.8GB 160 MB/s none
Disk113 (1,13) (0:14:00) 146.8GB 160 MB/s none
Disk114 (1,14) (0:15:00) 146.8GB 160 MB/s none
Notes:
The speed is the currently negotiated speed to the disk. This may be
less than the maximum speed supported by the device due to bus faults,
loss of signal integrity, etc.
See also show unit
locate
newpage pi
1510i Modular Smart Array Command Line Interface user guide
109
Vista de pagina 108
1 2 ... 104 105 106 107 108 109 110 111 112 113 114 ... 153 154

Comentarios a estos manuales

Sin comentarios