Hp StorageWorks 1510i Modular Smart Array Manual de usuario Pagina 69

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 154
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 68
show perf start perf
stop perf clear perf
show cacheinfo show taskstats
set debug show eventlog
Example help add unit command and response
CLI> help add unit
Usage: ’add unit <#> raid_level=R
data=diskrange
[spare=diskrange]
[stripe_size=S]
[size=X<GB|MB>]
[max_boot=<enable/disable>]
[cache=<enable/disable>]
#={0-31} / R={0,1,5,6(ADG)} / X={positive integer} / S={8,16,32,64,128,256}
diskrange examples: DISK101
DISK101-DISK105
"DISK101 DISK112-DISK202 DISK314"
DISKxyy: x={1,2,3} (box #) / yy={01-14} (bay #)
ex: DISK111 - disk in box 1, bay 11
max_boot is enabled by default. it can be disabled for OS’s that don’t
support the creation of bootdrives > 4GB
cache is enabled by default. enables/disables cache for the new unit.
add unit creates a new logical unit using the specified settings
newpage pi
1510i Modular Smart Array Command Line Interface user guide
69
Vista de pagina 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 153 154

Comentarios a estos manuales

Sin comentarios