Installation 63
Installation
Install the Disk System
1 Remove the power supply/fan modules to prepare the disk system for lifting:
a Loosen the screws in the extractor handles of each power supply/fan
module with the chassis still in the box.
b Pull the extractor handles out from the center of the power supply to
disengage it from the midplane. Pull each power supply/fan module out of
the chassis. Support the far end of the power supply/fan module with your
free hand as it clears the chassis.
c Set the power supply/fan modules aside, on an antistatic pad, to be
reinstalled later.
WA RN IN G An empty disk system weighs approximately 54 pounds (24.5 kg).
To avoid personal injury, it is recommended that two people install
the storage device in the rack.
2 Remove the disk modules from the disk system. Place them aside on the pink
antistatic foam pad supplied with your disk system.
3 Carry the disk system to the front of the rack and slide the back end onto the
rails (Figure 35) with the help of another person or using a lifting device.
Push the disk system into the rack as far as it will go.