Hp StorageWorks 2405 Disk System Manual de usuario Pagina 64

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 144
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 63
64 Installation
Step 4: Configure LCCs
The disk system comes with two LCCs installed.
If you are connecting this disk system to an HP StorageWorks Virtual Array 7400
or to a 1 Gb/s hub, the link speed switch must be set to 1 Gb/s.
1 Attach your ESD strap to ground.
2 Remove the LCC from the disk system chassis.
Caution Do not touch the pins on the back of the LCC.
3 Set internal configuration dip switch to appropriate link speed.
Be sure to set the internal LCC data transmission speed switch to 1
Gb/s or 2 Gb/s as appropriate for your configuration. See Figure 2.29
for more detailed information.
Vista de pagina 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 143 144

Comentarios a estos manuales

Sin comentarios