145
Server Specifications
In This Section
Environmental Specifications.....................................................................................................145
Server Specifications ..................................................................................................................145
Environmental Specifications
Temperature range* Specification
Operating
10°C to 35°C (50°F to 95°F)
Shipping
-40°C to 70°C (-40°F to 158°F)
Maximum wet bulb temperature
28°C (82.4°F)
Relative humidity
(noncondensing)**
Specification
Operating 10% to 90%
Non-operating 5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m
(1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C
(113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa.
Server Specifications
Dimensions Specification
Height 44.45 cm (17.50 in)
Depth (with bezel) 64 cm (25.2 in)
Width 22 cm (8.66 in)
Weight (no drives installed) 27.22 kg (60 lb)