Server Cabling 89
NOTE: Both SCSI channels are self-terminating. If you choose to not
use one or both of the SCSI channels, you do not need to terminate the
unused channel(s).
Cabling SCSI Devices in the Removable Media Area
The following steps detail the procedure for cabling an integrated SCSI controller
to a removable media or other device:
1. Install removable media device ("Installing a Half-Height or Full-Height
Media Device Option" on page 60
). Be sure that the SCSI ID is uniquely set
on each device.
2. Locate the SCSI cable that is shipped with the option. For more information
on cables, refer to the HP website
(http://www.hp.com/servers/proliantml350
).
3. Install the next available connector to the device.
SATA or SAS Cabling
Many configurations are possible when SATA or SAS controllers are added.
When upgrading your storage controller, refer to the Quickspecs and the cabling
matrix to identify the correct cables
(http://www.hp.com/products/servers/proliantml350/
).