Hp ProLiant ML350 G4 Server Manual de usuario Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 156
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
20 HP ProLiant ML350 Generation 4p Server User Guide
System LED and
Color
Internal Health
LED Color
Status
DIMM failure, slot X
(Amber)
Red
DIMM in slot X has failed.
DIMM in slot X is an unsupported type, and no valid
memory exists in another bank.
Amber
DIMM in slot X has reached single-bit correctable
error threshold.
DIMM in slot X is in a pre-failure condition.
DIMM in slot X is an unsupported type, but valid
memory exists in another bank.
Overtemperature
(Amber)
Red
The Health Driver has detected a cautionary
temperature level.
The server has detected a hardware critical
temperature level.
Fan (Amber) Red The minimum fan requirements are not being met. Fan
has failed.
Amber A fan has failed but still meets the minimum fan
requirements (with redundant fan option only).
Hot-Plug Hard Drive IDs
SCSI models of the HP ProLiant ML350 Generation 4p server support single- or
dual-channel SCSI hard drive configurations. The single-channel configuration
(simplex) supports up to six SCSI hard drives on one channel. The dual-channel
configuration (duplex) supports two SCSI hard drives on one channel (SCSI IDs
4 and 5) and up to four SCSI hard drives on the other channel (SCSI IDs 0
through 3) with the duplex option.
The SCSI IDs for both simplex and duplex configurations are illustrated. Always
populate hard drive bays starting with the lowest SCSI ID.
Vista de pagina 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 155 156

Comentarios a estos manuales

Sin comentarios