Component identification 19
Item Description Status
14 Board status LED
Off = Power off - memory board locking switch not
engaged or invalid memory configuration.
Green = Normal operation
Flashing green = Board is rebuilding
Flashing amber = DIMM on this board encountered
memory errors
Flashing amber = one of the following conditions:
Unlocking a memory board that should not be
removed
Attempting to insert a memory board at runtime
that fails
*The following applies to an invalid AMP error. This error occurs when the current memory configuration is not valid
for the configured AMP mode:
To keep the selected mode, modify the DIMM/board configuration. Refer to the memory
overview section ("Memory board LEDs and components" on page 17).
To change the selected mode, run RBSU and change the AMP mode. Refer to "HP ROM-Based
Setup Utility (on page 80)" for more information.
NOTE: If the Online Spare, Mirrored, and RAID LEDs are off, the server is in Advanced ECC mode. Refer to
"HP ROM-Based Setup Utility (on page 80)" for more information.
The following table illustrates the different LED combinations for a correctly configured memory board.
LED
Advanced ECC
memory
Online spare
memory
Hot-plug
mirrored
memory
Hot-plug RAID
memory
Board status Green Green Green Green
DIMM 1 to 6,
if populated
Green Green Green Green
Online spare
status
Off Green Off Off
Mirrored
status
Off Off Green Off
RAID status Off Off Off Green
Board
removable
Off Off Green Green