Hardware options installation 34
3.
Place the server on a flat, level work surface.
4. Remove the access panel.
CAUTION: Any attempt to remove an installed TPM from the system board breaks or disfigures
the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM,
administrators should consider the system compromised and take appropriate measures to ensure
the integrity of the system data.
5. Install the TPM board. Press down on the connector to seat the board.
6. Install the TPM security rivet by pressing the rivet firmly into the system board.
7. Install the access panel.
8. Install the server ("Installing the server into the chassis" on page 20).
9. Power up the server (on page 22).