Hp ProLiant SL335s G7 Server Manual de usuario Pagina 67

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 82
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 66
Specifications 67
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating
10
°
C to 35
°
C (50
°
F to 95
°
F)
Shipping
-30°C to 50°C (-22°F to 122°F)
Storage
-30°C to 60°C (-22°F to 140°F)
Maximum wet bulb temperature
28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating
10% to 90%
Non-operating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
Server specifications
Specification Value
Dimensions
Height
17.68 cm (6.96 in)
Depth
89.71 cm (35.32 in)
Width
44.8 cm (17.63 in)
Weight (maximum)
84 kg (185.2 lb)
Weight (no drives installed)
60 kg (132.3 lb)
Input requirements
Rated input voltage
90140 VAC
180264 VAC
Rated input frequency
4763 Hz
Rated input current
7.31 A at 115 VAC
3.6 A at 230 VAC
Rated input power
855 W at 100 VAC input
840.72 W at 200 VAC input
Btus per hour
N/A
Power supply output
Rated steady-state power
750 W at 100 VAC input
1200 W at 200240 VAC input
System input requirements information is based on measurements with hardware available at the time of publishing this
document. For updated information, see the HP website (http://www.hp.com/servers/powercalculator).
Vista de pagina 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72 ... 81 82

Comentarios a estos manuales

Sin comentarios