Table 38 Controller power supply output specications
Voltage Specication
Minimum
Nominal
Maximum
+3.3 VDC
Output Voltage Steady state current
Power
3.23 VDC 3.30 VDC
3.36 VDC 18 A
59 .4W
+5.1 VDC
Output Voltage Steady state current
Power
4.80 VDC
5.00 VDC
5.25 VDC 5.0 A
25.5 W
Total Current Total Power
24 A 105.6 W
1. +3.3 VDC steady state c urrent requires a minimum 5.0-V load of 1 A.
2. Total power includes 14 .0 watts for the internal blower.
Table 39 den
es the AC input current and wattage to the c ontroller power supplies.
Table 39 AC input current and wattage
Nominal
Maximum
Input Voltage
Amps Watts Amps Watts
60-Hz input
100 VAC
0.928
94
1.53 150
120 VAC
0.788
94
1. 25
148
208 VAC
0.576 97 0.73
146
50Hz Input
220 V AC
0.616 102 0. 69
146
240 VAC
0.573 100
0.64 147
Environm
ental specications
There are no controller environmental specications. See Environmental specications for this information.
Rack specications
Physical specications
WARNING!
The weight of the drive enclosure with the elements installed always requires at least two individuals to
move. HP recommends using a fork lift or a hand truck to move an enclosure in the shipping container.
Table 40 through Table 45 dene the dimensions and weights of the 9000-Series and 10000-Series
Enterprise Virtual Array racks.