0.F.en.03CRITICALconditionTransceiverbre channel drive enclosure bus fault
The system has de
tected a Fibre Channel drive enclosure bus fault involving a transceiver. This error
prevents the co
ntroller from transferring data on a loop and eliminates the enclosure dua l-loop capability.
Complete the fo
llowing procedure to correct this problem:
1. Record all six c
haracters of the condition report.
2. Check all the transceivers and cables to ensure they are properly connected.
3. Check all the transceivers on the loop to ensure they are compatible with the I/O module.
4. If the problem
persists, contact your HP authorized service representative.
0.F.en.04 CRITICAL condition—Transceiver removed
The EMU detects that a transceiver has been removed. This error remains active until the problem is xed.
Theerrorcanbeclearedbydoingoneofthefollowing:
1. Install a new transceiver,
or
Recongure the system by switching from a loop topology to one with Vixel switches, then the
transceiv er is not necessary.
2. Clear the error by resetting the EM U or by removing and then re-installing the I/O module.
0.F.en.05 C
RITICAL condition—Invalid bre channel character
This symptom can occur under the following conditions:
The incoming data stream is corrupted.
Acableisno
t completely connected.
The signal is degraded.
This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop
capability. This error remains active until the p roblem is xed.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
servi ce re
presentative.
Voltage sensor and current sensor conditions
The format of these sensor condition reports is 1. 2. e n . e c for a voltage sensor, and 1. 3. e n . e c for a
current sensor, where:
1. 2. is the voltage sensor element type
1. 3. is the current sensor element type number
en. is the sensor element num ber
ec is the error code
Table 51 lists the location of the power supply voltage and current sensors.
Table 51 Voltage an d c urrent sensor loca tion s
Sensor
Sensor Elem ent Location
01.
Power Supply 1 +5 VDC
02.
Power Supply 1 +1 2 VDC
03.
Power Supply 2 +5 VDC
04.
Power Supply 2 +1 2 VDC
HP StorageWorks 3000/5000 Enterprise Virtual Array user guide (VCS 4.xxx)