0107a
1
2
3
Figure 11 I/O module
1. Status indicators (Upper port, Power, and Lower port)
2. Upper port
3. Lower po
rt
TheI/Omodulesarefunctionallyidentical,butarenotinterchangeable.ModuleAcanonlybeinstalled
at the right end of the enclosure, and module B can only be installed at the left end of the enclosure. See
Figure 1 0
.
Each I/O m
odule has two por ts that can both transmit and receive data for bidirectional operation.
Activating a port requires connecting a FC cable to the port. The port function depends upon the
loop. See Figure 12.
CXO7954
A
3 1
4 2
Figure 12 Input and output ports
1. Lo o p A l owe r po r t
2. Loop A upper port
3. Loop B lower port
4. Loop B upper por t
I/O module status indicators
There are three status indicators on the I/O module. See Figure 11. The status indicator states for
an operational I/O module are shown in Table 7. Table 8 shows the status indicator states for a
non-operational I/O module.
HP StorageWorks 3000/5000 Enterprise Virtual Array user guide (VCS 4.xxx)
47