Correcting err ors
Correcting an error may r equire you to perform a specic set of actions. In some c ases, the only available
corrective act
ion is to replace the element.
Table 49 lists the element type cod es assigned to the drive enclosure elements.
Tab l e 49 Assig ned element type codes
Code Element
0.1.
Disk Drives
0.2.
Power Supplies
0.3.
Blowers
0.4.
Temperature Sensors
0.6
Audible Alarm
1
0.7.
EMU
0.C.
Controller OCP LCD
1
0.F.
Transceivers
1.0.
Language
1
1.1.
Communication Port
1
1. 2.
Voltage Sensors
1.
Current Sensors
8.0
Drive E nclosure
1
8.2.
Drive Enclosure Backplane
8.7.
I/O Modules
1
Does not generate a condition report. However, for any error, you should record the error code. Then, implement the
recommended corrective action.
Drive conditions
The format of a disk drive condition report is 0.1.en.ec,where:
0.1. is the disk drive element type number
en. is the two-character disk drive element
ec is the error code
A direct correlation exists between the disk drive element number and the bay number. However, no
direct correlation exists between the disk d rive bay number and the device Fibre Channel drive enclosure
physical address. The Fibre Channel drive enclosure physical address is assigned by negotiation
during system initialization.
The following sections dene the disk drive error codes.
0.1.en.01CRITICALconditionDriveconguration or drive link rate
As each drive spins up and comes on-line, the EMU determines if the drive is Fibre Channel compatible
and can operate at the link rate (1 Gbps or 2 Gbps) established by the I/O module. If either of these
conditions are not met, the EM U issues the condition report 0.1.en.01.
The corrective actions for these conditions are:
When the drive is not Fibre Channel-compatible you must install a Fibre Channel compatible
driveoradriveblank.