4. If steps 1, 2 or 3 did not reveal a problem, use HP Command View EVA to request the HSV210
controller to shut down the drive enclosure. Completing this action will halt the drive enclosure
data transfers.
5. Contact your authorized service re presentative and request assistance.
EMU conditions
TheformatofanEMUconditionreportis0.7.01.ec,where:
0.7.istheEMU
element type number
01. is the two-character EMU element num b er
ec is the error code
NOTE:
There is only
one EMU in a drive enclosure. Theref ore, the element number is always 01.
Resetting the EMU
In some cases, the only corrective action for an EMU error is to re place the EM U. Call your authorized
service representative if this action is required. Another option is to reset the EMU using the following
procedure.
1. Firmly grasp the EMU mounting handle and pull the EMU partially out of the enclosure.
NOTE:
You do not need to remove the EMU from the enclosure or disconnect the cables. You must
avoid putting any strain on the cables or connectors.
2. Wait 30 sec
onds, and then p ush the EMU in and fully seat the element in the backplane.TheEMU
should display any enclosure condition report within t wo minutes.
07.01.01 CRITICAL condition—EMU internal clock
There is an internal EMU clock error that will remain active until the problem is corrected.
Complete the following procedure to correct this problem.
1. Record all six characters of the condition report.
2. Reset the EMU.
3. If resetting the EMU did not correct the problem, replace the EMU.
4. Observe the EMU to ensure the error is corrected.
5. If unable to correct the problem, contact your HP authorized service representative.
07 .01 .0
2 UNRECOVERABLE condition—EMU interrupted
The Inte
r-IC(I2C)busisnotprocessingdataandtheEMUisunabletomonitororreportthestatusofthe
elements or enclosures. IMMED IATE corrective action is re quired to ensure proper enclosure operation.
This condition report remains active until the problem is corrected.
Comple
te the following procedure NOW to correct this problem.
1. Record
all six characters of the condition report.
2. Reset the EMU.
3. Observe the EMU to ensure the error is corrected.
128
EMU-generated c ondition reports