Table 41 Command error messages (continued)
ValueRecommended actionConditionError
message
Error code
234Please issue the pairresync
command manually to the identified
Detected a suspended status
(PSUE) for the paired
volume, before it made it to
the designated status.
Pair suspended at
WAIT state
EX_EWSUSE
failed paired volume to try to recover
it. If the trouble persists, contact HP
Technical Support.
233Please increase the value of the
timeout using the -t option.
Detected a time out, before
it made it to the designated
status.
Timeout waiting for
specified status
EX_EWSTOT
232Please confirm that HORC Manager
on the remote host is running.
Timeout error because the
remote did not notify about
expected status in time.
Timeout waiting for
specified status on
the local host
EX_EWSLTO
231Please confirm the value of “poll” in
the configuration file.
HORC Manager monitoring
was refused.
HORCM Monitor
stopped
EX_ESTMON
230Please confirm the command name.An unknown command was
attempted.
Unknown commandEX_UNWCMD
229Please confirm the pair status using
the pairdisplay command.
The pair status of a volume
within a group is not
identical to the status of the
other volumes in the group.
Inconsistent status in
group
EX_INCSTG
228Please confirm the pair status using
the pairdisplay command.
The pair status of the target
volume is not appropriate.
Invalid pair statusEX_INVSTP
222Please confirm the pair status using
the pairdisplay -l command.
The volume status of the
target volume is not
appropriate.
Invalid volume statusEX_INVVOL
220Please confirm the MU# for the
specified group using the
The MU# of the volume to
be operated is not
appropriate.
Invalid mu# with
HORC or HOMRCF
EX_INVMUN
pairdisplay command. MU #1/2
cannot be used for Continuous
Access Synchronous, and MU #1/2
must be P-VOL for Business Copy.
227Please confirm that the Port, Target
ID, LUN are defined correctly under
A device defined in the
configuration file does not
No such LDEV within
the RAID
EX_ENLDEV
HORCM_DEV in the configuration
file.
have a mapping to a real
LUN and target ID within the
RAID storage system.
226Call HP Technical Support.Wrong return code.Invalid return codeEX_INVRCD
225Check the volume list to see if an
operation was directed to the wrong
S-VOL.
Currency check error for
S-VOL. Cannot guarantee
identical data on S-VOL.
S-VOL currency errorEX_VOLCUR
224Please confirm the pair status of the
local volume.
The volume specified with
the S-VOL-takeover
Local volume
currency error
EX_VOLCUE
command is not the same as
the P-VOL.
223Please confirm the pair status of
remote and local volumes using the
pairdisplay command.
The combination of the
volumes specified with
Swap-takeover is unsuitable.
Local and remote
vol. currency error
EX_VOLCRE
--Call HP Technical Support.Wrong error code.Unknown error
code.
EX_UNWERR
Error messages and error codes 197