Table 84 SSB codes that are returned by raidcom modify rcu command (continued)
raidcom modify rcu
DescriptionError codeExecuting/
Async
Error message
SSB2SSB1
The operation cannot be done because the number of paths
become less than the least path number.
31012E23ExecutingCMDRJE
Command cannot be executed because the RCU identification
code of a path is invalid.
30012E31AsyncGet Command Status
An internal error occurred.00EF2ED6ExecutingCMDRJE
Call HP Technical Support.
The value of SSID for the remote storage system is invalid.33002ED6ExecutingCMDRJE
Table 85 SSB codes that are returned by raidcom delete rcu_path command
raidcom delete rcu_path
DescriptionError codeExecuting/
Asynchronous
Error message
SSB2SSB1
The CU# of RCU exceeds the effective value.30012E00ExecutingCMDRJE
The product ID or the path registration ID is invalid.30052E00ExecutingCMDRJE
Command cannot be executed because the parameter of
specified RCU is invalid.
30082E00AsynchronousGet Command Status
The specified port # on the side of RCU is invalid.32002E00ExecutingCMDRJE
CU number is out of effective range.71002E00Executing/
Asynchronous
CMDRJE
Get Command Status
The value of specified port is invalid.84002E00ExecutingCMDRJE
/AsynchronousGet Command Status
Failed to establish a path or the deletion operation. The following
factor can be thought.
31012E10AsynchronousGet Command Status
• Input parameter is invalid.
• Port status or the MP Blade status is in the state of abnormal.
• Cable is not connected correctly.
• Port is specified incorrectly.
The operation cannot be done because the microcode is being
changed.
80042E11AsynchronousGet Command Status
The command cannot be accepted. After a while, execute the
same command.
94002E11ExecutingCMDRJE
A logical path cannot be deleted because the specified RCU is
not registered.
30012E20AsynchronousGet Command Status
The specified CU number is not defined, or an LDEV is not
defined under the CU number.
71012E21AsynchronousGet Command Status
The operation cannot be done because the number of paths
become less than the least path number.
31012E23AsynchronousGet Command Status
The port attribute is not Initiator (MCU).840A2E30ExecutingCMDRJE
Command cannot be executed because the RCU identification
code of a path is invalid.
30012E31AsynchronousGet Command Status