Table 83 SSB codes that are returned by raidcom add thp_pool command (continued)
raidcom add thp_pool
DescriptionError codeExecuting/
Async
Error message
SSB2SSB1
External volumes whose cache modes are different are included.00182E31AsyncGet Command Status
The POOL Name is duplicated with another pool.60012E31ExecutingCMDRJE
The pool cannot include volumes in different RAID levels because
the pool cannot include those volumes. Or the pool cannot
60042E31AsyncGet Command Status
include the RAID 1 volumes and the volumes of other RAID levels
together.
The pool cannot include both internal volumes and external
volumes because the pool is not set to Mixable.
60052E31AsyncGet Command Status
The usage capacity exceeds the license capacity of program
product.
90002E31AsyncGet Command Status
The command cannot be accepted. After a while, execute the
same command.
00EE2EE7ExecutingCMDRJE
An internal error occurred.FEEC2EE7ExecutingCMDRJE
Call HP Technical Support.AsyncGet Command Status
Table 84 SSB codes that are returned by raidcom modify rcu command
raidcom modify rcu
DescriptionError codeExecuting/
Async
Error message
SSB2SSB1
CU# of RCU exceed the effective value.30012E00ExecutingCMDRJE
The value of least path number is invalid.30022E00ExecutingCMDRJE
The value of RIO MIH time is invalid.30032E00ExecutingCMDRJE
The value of Round-trip response time is invalid.30042E00ExecutingCMDRJE
Invalid product ID or path registration ID.30052E00ExecutingCMDRJE
Incident that is created by CU is not in the one of followings.30072E00ExecutingCMDRJE
- Incident that is sent to MCU host and RCU.
- Incident that is sent to RCU.
Command cannot be executed because the parameter of
specified RCU is invalid.
30082E00AsyncGet Command Status
Command cannot be executed because all the CU numbers in
the RCU is not unified at the path that is specified creation or
deletion.
30092E00AsyncGet Command Status
CU number is out of effective range.71002E00ExecutingCMDRJE
The operation cannot be done because the microcode is being
changed.
80042E11ExecutingCMDRJE
The serial number, the product ID, or the SSID of the target
storage system is incorrect.
30002E20ExecutingCMDRJE
The attribute of the RCU cannot be changed because the
specified RCU is not registered.
30012E20ExecutingCMDRJE
The specified CU number is not defined, or an LDEV is not
defined under the CU number.
71012E21AsyncGet Command Status