Table 46 SSB codes that are returned by raidcom add external_grp command (continued)
raidcom add external_grp
DescriptionError codeExecuting/
Asynchronous
Error message
SSB2SSB1
Exceeded the number of mapping that can be set per 1 port.41022E23AsynchronousGet Command Status
The operation cannot be done because the number of path in
the path group exceeds 8.
43032E23AsynchronousGet Command Status
The external volume cannot be added because the number of
virtual volumes that can be created in the system exceeded the
maximum number.
41192E30AsynchronousGet Command Status
The specified external LU has mapped already.42012E30AsynchronousGet Command Status
The port attribute is not External.84002E30ExecutingCMDRJE
The specified external storage LU is the device of not supported.40002E31AsynchronousGet Command Status
The specified external storage system is not supported.40012E31AsynchronousGet Command Status
The usage capacity exceeds the licence capacity of the program
product.
90002E31AsynchronousGet Command Status
The command cannot be accepted. After a while, execute the
same command.
00EE2EDAExecutingCMDRJE
An internal error occurred.41FA2EDAAsynchronousGet Command Status
The specified parameter is invalid. Check the HP P9000 RAID
Manager Reference Guide.
41022EF3ExecutingCMDRJE
Table 47 SSB codes that are returned by raidcom check_ext_storage external_grp command
raidcom check_ext_storage external_grp
DescriptionError codeExecuting/
Asynchronous
Error message
SSB2SSB1
The external volume group is not in the effective range.41002E00ExecutingCMDRJE
The specified external volume has already disconnected the
path, or is in the process of checking path.
43012E10ExecutingCMDRJE
The target LDEV is blocked.001B2E11ExecutingCMDRJE
The path for the specified external path is in the state of
disconnected.
40002E11ExecutingCMDRJE
All the paths for the specified external path are blocked.43022E11ExecutingCMDRJE
There is no external volume group.41002E20ExecutingCMDRJE
There is no external path.43002E20ExecutingCMDRJE
Online from the mainframe host.001E2E30ExecutingCMDRJE
An internal error occurred by the operation of external path.09052EDAAsynchronousGet Command Status
Call HP Technical Support.
An internal error occurred by the operation of external volume.09052EDAExecutingCMDRJE
Call HP Technical Support.
206 Troubleshooting
Vista de pagina 205
1 2 ... 201 202 203 204 205 206 207 208 209 210 211 ... 273 274