
Table 85 SSB codes that are returned by raidcom delete rcu_path command (continued)
raidcom delete rcu_path
DescriptionError codeExecuting/
Asynchronous
Error message
SSB2SSB1
Command cannot be executed because the serial number is not
unified in the specified path.
31012E31AsynchronousGet Command Status
The command cannot be accepted. After a while, execute the
same command.
00EE2ED6ExecutingCMDRJE
An internal error occurred.30052ED6AsynchronousGet Command Status
Call HP Technical Support.
The specified parameter is invalid. Check the HP P9000 RAID
Manager Reference Guide.
30022EF3ExecutingCMDRJE
Table 86 SSB codes that are returned by raidcom add rcu_path command
raidcom add rcu_path
DescriptionError codeExecuting/
Asynchronous
Error message
SSB2SSB1
CU# of RCU exceeds the effective value.30012E00ExecutingCMDRJE
Invalid product ID or path registration ID.30052E00ExecutingCMDRJE
Command cannot be executed because the parameter of
specified RCU is invalid.
30082E00AsynchronousGet Command Status
Command cannot be executed because all the CU numbers in
the RCU is not unified at the path that is specified creation or
deletion.
30092E00AsynchronousGet Command Status
The value of port # on the side of RCU is invalid.32002E00ExecutingCMDRJE
CU number is out of effective range.71002E00ExecutingCMDRJE
/AsynchronousGet Command Status
The value of specified port is invalid.84002E00ExecutingCMDRJE
/AsynchronousGet Command Status
Failed to establish a path or the deletion operation. The following
factor can be thought.
31012E10AsynchronousGet Command Status
• Input parameter is invalid.
• Port status or the MP Blade status is in the state of abnormal.
• Cable is not connected correctly.
• Port is specified incorrectly.
The operation cannot be done because the microcode is being
changed.
80042E11AsynchronousGet Command Status
The command cannot be accepted. After a while, execute the
same command.
94002E11ExecutingCMDRJE
The serial number, the product ID, or the SSID of the target
storage system is incorrect.
30002E20AsyncGet Command Status
A logical path cannot be added because the specified RCU is
not registered.
30012E20AsynchronousGet Command Status
The specified CU number is not defined, or an LDEV is not
defined under the CU number.
71012E21AsynchronousGet Command Status
Error messages and error codes 249
Comentarios a estos manuales