Table 78 SSB codes returned by raidcom modify snapshot (continued)
raidcom modify snapshot
DescriptionError codeExecuting/AsyncError message
SSB2SSB1
The command ends abnormally because the shared memory
(SS3 or more) is not expanded for necessary capacity.
81082E21ExecutingCMDRJE
The program product is not installed.90102E21ExecutingCMDRJE
The Fast Snap or Snapshot pair cannot be restored because
the volume that is set the S-VOL Disable is specified as the
P-VOL.
00792E30ExecutingCMDRJE
The command ends abnormally because the volume other
than OPEN-V is specified as the P-VOL of a Fast Snap or
Snapshot pair.
007A2E30ExecutingCMDRJE
The command ends abnormally because the external volume
mapped for the online data migration is specified as the
S-VOL of a Fast Snap or Snapshot pair.
00812E30ExecutingCMDRJE
The specified operation is not supported in the current
microcode version.
80002E3FExecutingCMDRJE
An internal error occurred. Call HP Technical Support.FEEC2EC6ExecutingCMDRJE
The specified parameter is invalid. Check the HP P9000
RAID Manager Reference Guide.
00022EF3ExecutingCMDRJE
Table 79 SSB codes returned by raidcom get snapshot
raidcom get snapshot
DescriptionError codeExecuting/AsyncError message
SSB2SSB1
An internal error occurred. Call HP Technical Support.FEEC2EC5ExecutingCMDRJE
Table 80 SSB codes returned by raidcom delete snapshot
raidcom delete snapshot
DescriptionError codeExecuting/AsyncError message
SSB2SSB1
The value exceeds the range of LDEV number.00002E00ExecutingCMDRJE
The MU number exceeds the maximum.000B2E00ExecutingCMDRJE
The command ends abnormally because the volume out of
the range of LDEV number is specified as the P-VOL of a
Fast Snap or Snapshot pair.
00282E00ExecutingCMDRJE
The command ends abnormally because the Business Copy
reserved volume is specified as the P-VOL of a Fast Snap
or Snapshot pair.
00332E10ExecutingCMDRJE
The command ends abnormally because the Auto LUN
source volume is specified as the P-VOL of a Fast Snap or
Snapshot pair.
00342E10ExecutingCMDRJE
The command ends abnormally because the Auto LUN
target volume is specified as the P-VOL of a Fast Snap or
Snapshot pair.
00352E10ExecutingCMDRJE