Table 98 SSB codes that are returned by raidcom delete host_grp command
raidcom delete host_grp
DescriptionError codeExecuting/
Asynchronous
Error message
SSB2SSB1
The cancelling of the host mode option 61 setting was aborted.302CB956ExecutingCMDRJ
The program product is not installed.304FB956ExecutingCMDRJE
The value of host group ID exceeds the maximum.3071B956ExecutingCMDRJE
The attribute of the specified port is Initiator or External.3077B956ExecutingCMDRJE
Deletion cannot be executed because the last path of Business
Copy is included in the host group.
3203B956ExecutingCMDRJE
Deletion cannot be executed because the last path of Snapshot
is included in the host group.
320AB956ExecutingCMDRJE
The command device being used at the local RAID Manager
exists under the host group.
3239B956ExecutingCMDRJE
Table 99 SSB codes that are returned by raidcom add host_grp command
raidcom add host_grp
DescriptionError codeExecuting/
Asynchronous
Error message
SSB2SSB1
The program product is not installed.304FB956ExecutingCMDRJE
The value of host group ID exceeds the maximum.3071B956ExecutingCMDRJE
The attribute of the specified port is Initiator or External.3077B956ExecutingCMDRJE
The same host group name is already installed in the specified
port.
3173B956ExecutingCMDRJE
The default host group name cannot be registered for the host
group ID is other than 0.
3174B956ExecutingCMDRJE
Table 100 SSB codes that are returned by raidcom modify host_grp command
raidcom modify host_grp
DescriptionError codeExecuting/
Asynchronous
Error message
SSB2SSB1
The command device being used at the local RAID Manager
exists under the host group.
0339B958ExecutingCMDRJE
Changing of the host mode/ host mode option cannot be
executed for the port of Initiator or External.
0350B958ExecutingCMDRJE
The invalid host mode is specified.0354B958ExecutingCMDRJE
The cancelling of the host mode option 61 setting was aborted.092CB958ExecutingCMDRJE
The host group ID exceeds the maximum.0956B958ExecutingCMDRJE
The program product is not installed.0957B958ExecutingCMDRJE
The specified host group is not installed.0959B958ExecutingCMDRJE
The command device being used at the local RAID Manager
exists under the host group.
B9F9B9F9ExecutingCMDRJE
Error messages and error codes 257