Working with Disks
After setting the S.M.A.R.T. interval timer, use the disk show
smart command to verify the exception interval timer setting.
Displaying and Setting the Report Count
The report count attribute indicates the number of times that
S.M.A.R.T. can report an exception.
The CLI allows you to do the following:
Display the S.M.A.R.T. report count setting for your disks
Set the S.M.A.R.T. report count
To display the S.M.A.R.T. report count setting for your disks, use the
disk show smart command, as in the following example. Note
that the Report Count column appears only if you specify the
/full switch with the disk show smart command. In the
following example, the Report Count column shows the number of
times an exception can be reported, which is once for devices (2,1,0)
and (2,2,0). A value of 0 in the Report Count column indicates that
there is no limit to the number of times an exception can be reported.
(Note that the example eliminates some items in the disk show
smart display to make the example readable on this page.)
HPN0> disk show smart /full=TRUE
Executing: disk show smart /full=TRUE
Smart
Capable Log Interval Report Error
C:ID:L Device Errors Timer (secs.) Count Count
------ ------- ------ ------------- ------ -----
2:01:0 Y N 0 1 0
2:02:0 Y N 0 1 0
To set the S.M.A.R.T. exception report error count, use the disk
set smart command with the /report_count switch. The
following example shows how to set the S.M.A.R.T. exception report
count to 1 on SCSI device (2,1,0):
HPN0
>
disk set smart /report_count=1 (2,1,0)
Executing: disk set smart /report_count=1
(CHANNEL=2,ID=1,LUN=0)
SMART parameters on disk (2,01,0) were successfully set.