Hp ProLiant DL580 G3 Server Manual de usuario Pagina 32

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 190
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 31
32 HP ProLiant DL580 Generation 3 Server User Guide
Online/Activity
LED (green)
Fault/UID LED
(amber/blue)
Interpretation
Off Steadily amber A critical fault condition has been identified for this drive, and
the controller has placed it offline. Replace the drive as soon
as possible.
Off Amber, flashing
regularly (1 Hz)
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
Off Off The drive is offline, a spare, or not configured as part of an
array.
Fan locations
The server is shipped with six system fans. Each fan is hot-swappable and
independently controlled. The fans are distributed into two zones to control
thermal conditions within the server.
Zone 1 contains four fans (three, plus one redundant) to control the
temperature in the processor module area.
Zone 2 contains two fans (one, plus one redundant) to control the
temperature in the hard drive bay area.