44 HSG80 Users Guide
Troubleshooting Table
Use the troubleshooting checklist that begins on page 42 to find a
symptom, then use this table to verify and fix the problem.
Table 41 Troubleshooting Table
Symptom Possible Cause Investigation Remedy
Reset button not lit No power to subsystem. Check power to
subsystem and power
supplies on controllers
shelf.
Replace cord or AC
input power module.
Ensure that all cooling
fans are installed. If one
or more fans are
missing or all are
inoperative for more
than eight minutes, the
EMU shuts down the
subsystem.
Turn off power switch
on AC input power
module. Replace
cooling fan. Restore
power to subsystem.
Verify that the standby
power switch on the
PVA was not depressed
for more than five
seconds.
Depress the alarm
control switch on the
EMU.
Failed controller. If the foregoing check
fails to produce a
remedy, check for OCP
LED codes.
Replace controller.
Reset button lit steadily;
other LEDs also lit.
Various See Operator Control
Panel LED Codes,
page C2.
Follow repair action.
Reset button blinking;
other LEDs also lit.
Device in error or FAIL
set on corresponding
device port with other
LEDs lit.
SHOW device FULL Follow repair action.