LED Codes C3
Solid OCP Patterns
Table C1 Solid OCP Patterns
Pattern
OCP
Code
Error Repair Action
■●●●●●●
3F DAEMON diagnostic failed hard
in non-fault tolerant mode
DAEMON diagnostic detected
critical hardware component
failure; controller can no longer
operate
Verify that cache module is present. If
the error persists, replace controller.
■●●●●❍●
3D NVPM structure revision greater
than images
NVPM structure revision number
is greater than the one that can be
handled by the software version
attempting to be executed
Replace program card with one that
contains the latest software version
■●●●●❍❍
3C NVPM write loop hang
Attempt to write data to NVPM
failed
Replace controller
■●●●❍●●
3B NVPM read loop hang
Attempt to read data from NVPM
failed
Replace controller
■●●●❍●❍
3A An unexpected NMI occurred
during Last Failure processing
Last Failure processing interrupted
by a Non-Maskable Interrupt
(NMI)
Reset controller
■●●●❍❍●
39 NVPM configuration inconsistent
Device configuration within the
NVPM is inconsistent
Reset controller