Hp Array Controller HSG V8.7 Software Manual de usuario Pagina 211

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 576
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 210
Replacement Procedures 515
13. Hold the reset button while inserting the program card into the new
controller. Release the reset button and replace the ESD cover. The
controller will restart.
14. See Configuring an HSG80 Array Controller, page 23, to configure
the controller.
15. Enable failover, and re-establish the dual-redundant controller
configuration with the following command:
SET FAILOVER COPY=THIS_CONTROLLER
This command copies the subsystems configuration from this
controller to the new controller.
16. Disconnect the PC or terminal from the controllers maintenance port.
Replacing a Controller in a Dual-Redundant Controller Configuration
Use the following steps in Removing a Controller in a Dual-
Redundant Controller Configuration and Installing a Controller in a
Dual-Redundant Controller Configuration to replace a controller.
Removing a Controller in a Dual-Redundant Controller
Configuration
Use the following steps to remove a controller:
1. Connect a PC or terminal to the operational controllers maintenance
port. The controller to which youre connected is this controller; the
controller that youre removing is the other controller.
2. Disable failover and take the controllers out of their dual-redundant
configuration with the following command:
SET NOFAILOVER
3. Remove the program cards ESD cover and program card. Save them for
the replacement controller.
4. Start FRUTIL with the following command:
RUN FRUTIL
FRUTIL displays the following:
Do you intend to replace this controllers cache battery? Y/N