Replacement Procedures 521
Replacing a Cache Module in a Dual-Redundant Controller Configuration
Use the following steps in Removing a Cache Module in a Dual-
Redundant Controller Configuration and Installing a Cache Module
in a Dual-Redundant Controller Configuration to replace a cache
module.
Note The new cache module must contain the same memory
configuration as the cache module its replacing.
Removing a Cache Module in a Dual-Redundant
Controller Configuration
Use the following steps to remove a cache module:
1. Connect a PC or terminal to the operational controllers maintenance
port. The controller to which youre connected is this controller; the
controller that youre removing is the other controller.
2. Disable failover and take the controllers out of their dual-redundant
configuration with the following command:
SET NOFAILOVER
3. Remove the ESD cover and program card from the other controller.
Save them for reinstallation later.
4. Start FRUTIL with the following command:
RUN FRUTIL
FRUTIL displays the following:
Do you intend to replace this controllers cache battery? Y/N
5. Enter N(o). FRUTIL displays the FRUTIL Main menu:
FRUTIL Main Menu:
1. Replace or remove a controller or cache module
2. Install a controller or cache module
3. Replace a PVA module
4. Replace an I/O module
5. Exit
Enter choice: 1, 2, 3, 4, or 5 ->