Hp Array Controller HSG V8.7 Software Manual de usuario Pagina 477

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 576
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 476
Event Reporting: Templates and Codes D43
01950188 An error has occurred that caused the FX to be rest, when not permissible.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains the value of write diagnostic register 0.
Last Failure Parameter [3] contains the value of write diagnostic register 1.
Last Failure Parameter [4] contains the IBUS address of error register.
Last Failure Parameter [5] contains the PCFX PDAL control / status register.
Last Failure Parameter [6] contains the PCFX CDAL control / status register.
Last Failure Parameter [7] contains the current PDAL address of error register.
01960186 The Ibus is inaccessible.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains the value of read diagnostic register 2.
Last Failure Parameter [3] contains the value of write diagnostic register 0.
Last Failure Parameter [4] contains the value of write diagnostic register 1.
Last Failure Parameter [5] contains the IBUS address of error register.
01970188 Software indicates all NMI causes cleared, but some remain.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains the value of read diagnostic register 2.
Last Failure Parameter [3] contains the value of write diagnostic register 0.
Last Failure Parameter [4] contains the value of write diagnostic register 1.
Last Failure Parameter [5] contains the IBUS address of error register.
Last Failure Parameter [6] contains the PCFX PDAL control / status register.
Last Failure Parameter [7] contains the PCFX CDAL control / status register.
01982087 The Ibus encountered a parity error.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains the value of read diagnostic register 2.
Last Failure Parameter [3] contains the value of write diagnostic register 0.
Last Failure Parameter [4] contains the value of write diagnostic register 1.
Last Failure Parameter [5] contains the IBUS address of error register.
Last Failure Parameter [6] contains the RIP.
Table D3 Last Failure Codes (Continued)
Code Description
Vista de pagina 476
1 2 ... 472 473 474 475 476 477 478 479 480 481 482 ... 575 576

Comentarios a estos manuales

Sin comentarios