Hp Array Controller HSG V8.7 Software Manual de usuario Pagina 488

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 576
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 487
D54 HSG80 Users Guide
030B0188 A dip error was detected when pcb_busy was set.
Last Failure Parameter [0] contains the PCB port_ptr value.
Last Failure Parameter [1] contains the new info NULL-SSTAT0-DSTAT-ISTAT.
Last Failure Parameter [2] contains the PCB copy of the device port DBC register.
Last Failure Parameter [3] contains the PCB copy of the device port DNAD
register.
Last Failure Parameter [4] contains the PCB copy of the device port DSP register.
Last Failure Parameter [5] contains the PCB copy of the device port DSPS
register.
Last Failure Parameter [6] contains the PCB copies of the device port SSTAT2/
SSTAT1/SSTAT0/DSTAT registers.
Last Failure Parameter [7] contains the PCB copies of the device port LCRC/
RESERVED/ISTAT/DFIFO registers.
031E0100 Cant find in_error dwd on in-process queue.
031F0100 Either DWD_ptr is null or bad value in dsps.
03280100 SCSI CDB contains an invalid group code for a transfer command.
03290100 The required Event Information Packet (EIP) or Device Work Descriptor (DWD) were
not supplied to the Device Services error logging code.
032B0100 A Device Work Descriptor (DWD) was supplied with a NULL Physical Unit Block
(PUB) pointer.
03320101 An invalid code was passed to the error recovery thread in the error_stat field of the
PCB.
Last Failure Parameter[0] contains the PCB error_stat code.
Table D3 Last Failure Codes (Continued)