Upgrading the Subsystem 619
Note If the controller youre installing was previously used in another
subsystem, it will need to be purged of the controllers old
configuration (see CONFIGURATION RESET, page B45).
12. Wait for FRUTIL to terminate and connect the hub cables to the new
controller.
Note One or two hub cables may be attached, depending on the
configuration.
13. To allow the other controllerto restart, type the following command:
RESTART OTHER _CONTROLLER
14. Hold the reset button while inserting the program card into the
controller. Release the reset button and replace the ESD cover. The
controller will restart.
15. See Configuring an HSG80 Array Controller, page 23, to configure
the controller.
16. Enable failover, and re-establish the dual-redundant controller
configuration with the following command:
SET FAILOVER COPY=THIS_CONTROLLER
This command copies the subsystems configuration from this
controller to the other controller.
17. Disconnect the PC or terminal from the controllers maintenance port.