Enter/Exit Programming Mode 1D Symbologies
110
HP Retail Integrated Barcode Scanner
Industrial 2 of 5 Set Length 1
This feature specifies one of the barcode lengths for Industrial 2 of 5 Length Control. Length
1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed
Length Mode. Length includes the barcode’s data characte
rs only. The length can be set
from 0 to 50 characters.
Table 11 provides some examples for setting Length
1. See page 188 if you want detailed
instructions on setting this feature.
Table 11. Industrial 2 of 5 Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting 00 Characters 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Industrial 2 of 5 Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to
abort and not save the entry string. You can
then start again at the beginning.
CANCEL
DEFAULT
01 = Length 1 is 1 Character