Enter/Exit Programming Mode Reading Parameters
48
HP Retail Integrated Barcode Scanner
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following a
good read. The good read LED on time can be set within a range of 100 milliseconds to
25,500 milliseconds (0.1 to 25.5 seconds) in 100ms increments. A setting of 00 keeps the
LED on until the next trigger pull.
See page 198 in “References” for detailed instructions and
examples for setting this feature.
Good Read LED Duration Setting =
Keep LED on until next trigger pull
Select Good Read LED Duration Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE barcode above, then the
barcode at left followed by the digits from the
Alphanumeric characters in Appendix D, Keypad
representing your desired character(s). End by scan-
ning the ENTER/EXIT barcode again.
Make a mistake? Scan the CANCEL barcode to
abort and not save the entry s
tring. You can then start
again at the beginning.
CANCEL
003 = Good Read LED
stays on for 300 ms.
Indicators are dimmed during sleep.