Scanning Features
Programming Reference Guide
201
Multiple Labels Ordering by Code Symbology
This feature Specifies the transmission ordering by symbology type, when Multiple Labels
per Frame is enabled.Up to six symbologies can be selected. Zeroes must be added to pad
the string to 12 characters if not using all six symbologies.
The labels are ordered first as specified in the o
utput mask. Labels present in the volume but
not specified will be transmitted as unspecified symbologies in random order as allowed by
the reading time sequence. For each label decoded in the volume the scanner signals the
standard beeper and LED indications.
To specify the symbology order:
1. Determine the symbologies and order you want to specify.
2. Use Table 39 on page 202 to find the hex
values for up to six symbologies.
3. Go to page 56 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
4. Scan the barcode: “SELECT SYMBOLOGIES FOR MULTIPLE LABELS ORDER-
ING”.
5. Scan the appropriate two alphanumeric characte
rs from the keypad in Appendix D,
Keypad, that represent the desired character/value in step 2 above.
6. Scan zeroes if needed to make a 12-character string.
7. When finished, scan the ENTER/EXIT PROGRAMMING MODE barcode to exit
Pro
gramming Mode.
This completes the procedure. See Table 38 for some examples of how to set this feature.
Table 38. Multiple Labels Ordering by Code Symbology Examples
Table 39 on page 202 shows the hex value associated with each symbology.
STEP ACTION EXAMPLES
1 Desired symbology
Code 39 Data Matrix Code 128 Aztec
2 Hex equivalent from
Table 39
24 0E 0C 4E
3 Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT SYMBOLOGIES FOR MULTIPLE LABELS ORDERING
5
Scan Two Characters From
Appendix D, Keypad
‘2’ and ‘4’ ‘0’ and ‘E’ ‘0’ and ‘C’ ‘4’ and ‘E’
RESULT
0x240E0C4E0000
6 Scan ENTER/EXIT PROGRAMMING MODE