References
198
HP Retail Integrated Barcode Scanner
Reading Parameters
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following a
good read. The good read LED on time can be set within a range of 100 milliseconds to
25,550 milliseconds (0.1 to 25.5 seconds) in 100ms increments.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds.
A setting of 0 means that the good read
LED stays on until the next time the trigger is pulled.
2. Divide the desired setting by 10 (setting is in
100ms increments). Pad the result with
leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc.
3. Go to page 48 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
4. Scan the barcode: SELECT GOOD READ LED DURATION SETTING.
5. Scan the appropriate three digits from the keypad in Appendix D, Keypad representing
the duration which was determine
d in the steps above. You will hear a two-beep indi-
cation after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcod
e to exit Programming
Mode.
This completes the procedure. See Table 35 for some examples of how to set this feature.
Table 35. Good Read LED Duration Setting Examples
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the begin-
ning.
STEP ACTION EXAMPLES
1 Desired Setting
Good Read LED
stays on until next
trigger pull (00)
200ms 1500ms 25,500ms (25.5 sec.)
2
Divide by 10 (and pad with
leading z
eroes)
000 002 015 255
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan
SELECT GOOD READ LED DURATION SETTING
5
Scan Three Characters From
Appendix D, Keypad
‘0’, ‘0’ and ‘0’ ‘0’, ‘0’ and ‘2’ ‘0’, ‘1’ and ‘5’ ‘2’, ‘5’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE