Troubleshooting
Troubleshooting Your X.25 Link
Chapter 8200
Figure 8-1 Flowchart 1
Flowchart 2 – Procedures and Notes
Use these procedures to verify that your X.25 link is correctly initialized.
Read the following notes before carrying out the initialization check
procedures in Flowchart 2.
Note 2-1 – x25stat
Level 2 is down if x25stat -d [device] -f returns a level 2 link state
other than “normal.”
Note 2-2 – eisa_config
Sometimes x25init does not recognize the dual-port EISA interface
(J2815A) after a first-time installation. When you reboot your system
after installing the dual-port EISA interface, you may receive a message
similar to:
Device /dev/x25_0p1 is not configured in the kernel
Start
Go to Flowchart 2 Go to Flowchart 3 Go to Flowchart 4
Run x25stat
X.25 not initialized Level 2 down
Statistics dispayed