3-50 Hardware installation: Application Module (SNN/SNN-E)
553-4001-111 Standard 1.0 March 1997
2 Secure the Meridian MAX 8 for power down.
Refer to the
Meridian MAX 8 Maintenance and Diagnostics Guide
(NTP 553-4001-811), “Maintenance and Administration programs:
system shut down” chapter, “Restart and Power Down Utilities” section,
“Secure the System for Power Down” subsection, for more information.
3 Power down your system by flipping the power switch located to the left
of the AEM to the OFF position. Wait approximately 20 seconds.
4 Flip the power switch to the ON position.
The system displays the following at the maintenance console. (The
CPU card being configured [MVME167 or MVME177] appears in the
message instead of “xxx”. ) Your system messages may differ.
Copyright Motorola Inc. 1988 – 1994, All Rights Reserved
MVMExxx Debugger/Diagnostics Release Version 2.2 – 01/14/94
COLD Start
Local Memory Found =
xxxxxxx (&xxxxxxxx)
Note
: (The “xxxxxxx (&xxxxxxxx)” will be 04000000 (&67108864) for
SNN-E, 02000000 (&33554432) for SNN, and 01000000 (&16777216)
for IPE/IPE-E.)
5 If your card was preset in the factory, go to Step 8.
If your card was not preset in the factory, the following message
appears:
Autoboot in progress... To abort hit <BREAK>
6 Press the {BREAK} key.
Note:
{F5} on the VT520 and VT420 is equivalent to the {BREAK} key.
––Break Detected––
The following menu may be shown. If it does not appear, go to Step 8.
1) Continue System Start Up
2) Select Alternate Boot Device
3) Go to System Debugger
4) Initiate Service Call
5) Display System Test Errors
6) Dump Memory to Tape
Enter Menu #: