3-42 Hardware installation: Application Module (SNN/SNN-E)
553-4001-111 Standard 1.0 March 1997
VME multiport cable
This cable, seen in Figure 3-17, connects the Meridian MAX module with
each peripheral in the system. Each cable has a single male DB-25 plug at
one end, and three female DB-25 plugs at the other end. The single DB-25
plug connects to a DB-25 socket on the Generic I/O panel. Each of the
three DB-25 plugs at the other end are connected to a peripheral device.
Refer to the correct port assignment chart when connecting peripherals to
cables.
An RS-232 straight-through cable with male DB-25 connectors can extend
the range between a Meridian MAX and a peripheral device. The RS-232
must be less than 13 meters (42 feet) long, and must use all 25 pins. For
greater distances, refer to the “Modems” chapter. The cables from
ACD-MAX 3.0 cannot be used by Meridian MAX.
Table 3-7 is the wiring table for the multiport cable. Note that all of the pins
listed in the “From” column represent pins in the plug which connect to the
Generic I/O panel. Pins listed in the “To” column are pins in the DB-25
sockets for the cables listed in the “Cable” column.
Table 3-7
VME multiport cable wiring
From To Cable Signal
name
From To Cable Signal
name
2 2 A TD 25 7 B GND
3 3 A RD 24 8 B CD
4 4 A RTS 23 20 B DTR
5 5 A CTS 14 2 C TD
6 6 A DSR 15 3 C RD
7 7 A GND 16 4 C RTS
8 8 A CD 17 5 C CTS
20 20 A DTR 18 6 C DSR
9 2 B TD 19 7 C GND
10 3 B RD 21 8 C CD
11 4 B RTS 22 20 C DTR
12 5 B CTS 1 1 A SHIELD
13 6 B DSR 1 1 B SHIELD