Hardware installation: Intelligent Peripheral Equipment module 4-15
Meridian MAX
Installation Guide
Product release 8
The connector panel assignment for Cable A (NT1R03AA) and Cable B
(NT1R03BA) in the Option 11 is shown in Table 4-2. The connector panel
assignment depends on the desired slot placement of the Meridian MAX
IPE/IPE-E module.
Before connecting the four-port cables, connect one extension cable
(NT1R03CA) to each connector, then connect each four-port cable. Make
sure the connectors are secure. This allows the front panel on the Option 11
to be closed without interference from too many dangling cables. For
example, if your Meridian MAX IPE/IPE-E module occupies slots 7, 8,
and 9, connect one end of an NT1R03CA extension cable to connector J9
while connecting Cable A to the other end of the extension cable. Connect a
second NT1R03CA extension cable to connector J7, attaching Cable B to
the other end of the second extension cable. Connector J8 is not used.
Replace the connector panel bar making sure the padded side is placed
against the back of the connectors.
Table 4-2
Option 11 peripheral cable connector assignment sheet (main cabinet)
Module slot combinations Cable
A B
2-4 J4 J2
3-5 J5 J3
4-6 J6 J4
5-7 J7 J5
6-8 J8 J6
7-9 J9 J7