72
Figure 55 Network diagram
Configuration procedure
This example uses a switch. The configuration on a router is the same.
1. Log in to the firewall module from the network device:
# Configure the AUX user interface of the firewall module.
<FW module> system-view
[FW module] user-interface aux 0
[FW module-ui-aux0] authentication-mode none
[FW module-ui-aux0] user privilege level 3
[FW module-ui-aux0]
# Log in to the firewall module.
<Switch> oap connect slot 3
Connected to OAP!
<FW module>
2. Configure the clock synchronization timer and the monitoring timer on the network device:
# Enable ACSEI server.
<Switch> system-view
[Switch] acsei server enable
# Enter ACSEI server view.
[Switch] acsei server
# Set the clock synchronization timer to 10 minutes.
[Switch-acsei server] acsei timer clock-sync 10
# Set the monitoring timer to 10 seconds.
[Switch-acsei server] acsei timer monitor 10
3. Enable ACSEI client on the Ten-GigabitEthernet 0/0 interface.
<FW module> system-view
[FW module] interface ten-gigabitethernet0/0
[FW module] acsei-client enable
4. Verifying the configuration:
# Restart the firewall module on the network device.
<Switch> oap reboot slot 3
This command will recover the OAP from shutdown or other failed state.
Warning: This command may lose the data on the hard disk if the OAP is not being
shut down! Continue? [Y/N]:y
Reboot OAP by command.
The output shows that you can restart the firewall module on the network device.
# Display the ACSEI server configuration information on the network device.
<Switch> display current-configuration configuration acsei-server