Update the alert subscriptions that were created without using an alert subscription template and are
congured to forward SNMP traps
a. In the Device Management navigation pane, go to Alerts > All Subscriptions.
b. In the All Subscriptions pane, select the alert subscription from the list, and then click the Edit
Subscription button. The Edit Subscription wizard starts.
c. Click the Next button until the Specify notication settings page appears.
d. In the SNMPv3 credential section, select SHA-1 from the Authentication protocol list, and select
AES-128 from the Privacy protocol list.
e. If required, enter the new values for the user name, authentication passphrase, and privacy
passphrase.
f. Click the Next button until the Conrm page appears.
g. On the Conrm page, verify that the information is correct, and then click the Edit Subscription button.
h. On the Results page, click the Done button.
i. Repeat steps b through h for each alert subscription that was created without using an alert
subscription template.
-or-
If any future changes are made to the alert subscriptions, all of the alert subscriptions must be changed. To
prevent this in the future, HP recommends that you use the following steps to create new alert
subscriptions that are linked to alert subscription templates:
a. In the Device Management navigation pane, go to Alerts > All Subscriptions.
b. In the All Subscriptions pane, select the alert subscription from the list, and then click the Unsubscribe
button. The Delete Alert Subscriptions wizard starts.
c. On the Conrm page, click the Unsubscribe button.
d. On the Results page, click the Done button.
e. In the Device Management navigation pane, go to Alerts > Templates.
f. In the Alerts - Subscription Templates pane, select the alert subscription template from the list, and
then click the Apply button. The Apply Alert Subscription Template wizard starts.
NOTE: If an alert subscription template is not available, create an alert subscription template that
meets your specic needs.
g. On the Select devices page, select the devices from the Available devices list, and then click the >
button.
h. Click the Next button.
i. To link the selected alert subscription template to this alert subscription, select the Link template to
subscription option. Changes that are made to the selected alert subscription template are
automatically applied to the devices that are associated with this alert subscription.
-or-
To create an alert subscription that is not linked to the selected alert subscription template, select the
Do NOT link template to subscription option, and then enter a name for this alert subscription in the
Subscription name box. Changes that are made to the alert subscription template are not applied to
the devices that were previously congured with this alert subscription template.