Message name / descriptionASCQASCSense
key
LU IS NOT READY, MANUAL INTERVENTION REQ'D
Initialization failed. Determine failure type by checking any previous
error code returned to host. Reinitialize element status through backup
package or command line interface.
03042
DOOR IS OPENED INVENTORY MAY HAVE BEEN CORRUPTED
Close door and retry command. If the system is on-line, it executes its
initialization procedure.
00802
DRIVE CLEAN REQUIRED.
A tape drive requires cleaning.
01802
SYSTEM IS STOPPED
The STOP button on the control panel was pressed. Press the STOP button
again to start the library.
07802
LOGICAL UNIT IS TURNED OFF-LINE
Through the Operations menu on the OCP, bring the library on-line.
09802
MAGAZINE NOT ACCESSIBLE
The tape cartridge magazine can not be accessed.
113B2
MAGAZINE NOT PRESENT
The tape cartridge magazine is not present.
123B2
OPERATOR MEDIUM REMOVAL REQUEST
Indicates that an element contains a cleaning cartridge that is “used-up”
and the library is unable to export the cleaning cartridge. Manually
unload the tape. The load port door is open, so import/export elements
can not be accessed.
015A2
DRIVE REPORTING MEDIA ERROR
The tape drive is indicating that it has detected a problem with the media.
• The tape in question should be removed from the library and dis-
carded.
• Check drive logs for more information.
00523
INTERNAL FAILURE00444
MOTOR POWER FAILURE
Indicates motor powered off for a reason not otherwise reported. Check
the cabinet controller and the umbilical. Check the 55V LED on the picker
to determine whether this is the motor that failed. Verify that the doors
are closed. Check the door sensors.
11804
BARCODE SCANNER FAILURE
Barcode scanner has failed. Run the Robotics to Home Position test from
the OCP. Run Calibrate Cabinet Test from the OCP and inventory the
cabinet.
23804
Sense data values128