Message name / descriptionASCQASCSense
key
ROTARY INVALID START CONDITION
Rotary hardware condition is unknown. Run the Robotics to Home Position
test from the OCP.
E0825
ROTARY INVALID COMMAND
Rotary axis was commanded to a position out of its legal range. This is
an internal code failure.
• Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
• Verify that the library and its components have the current firmware.
F0825
EXTENSION INVALID START CONDITION
Extension hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.
E0835
EXTENSION INVALID COMMAND
Extension hardware was commanded to a position out of the systems
mechanical limits.
• Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
• Verify that the library and its components have the current firmware.
F0835
VERTICAL INVALID START CONDITION
Vertical hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.
E0845
VERTICAL INVALID COMMAND
Vertical hardware commanded to position out of system mechanical
limits.
• Run the Robotics to Home Position test from the OCP.
• If the problem persists, calibrate the library.
• Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
• Verify that the library and its components have the current firmware.
F0845
HORIZONTAL INVALID START CONDITION
Horizontal hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.
E0855
HORIZONTAL INVALID COMMAND
Horizontal hardware commanded to position out of system mechanical
limits.
• Run the Robotics to Home Position test from the OCP.
• If the problem persists, calibrate the library.
• Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
• Verify that the library and its components have the current firmware.
F0855