Message name / descriptionASCQASCSense
key
DRIVE THREAD FAILED OR TIMED OUT
The command to the drive to thread a tape failed or timed out. Check
drive logs for more information.
23F34
DRIVE FW UPDATE IN PROGRESS
The drive can not perform indicated request because it is in the process
of updating it's firmware. Wait until the firmware update is complete,
then retry the operation.
07045
INVALID COMMAND OPERATION CODE
• Verify the host command format.
• Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
• Verify that the library and its components have the current firmware.
00205
INVALID ELEMENT ADDRESS
• Check Mode Sense data for correct element addresses.
• Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
• Verify that the library and its components have the current firmware.
01215
INVALID FIELD IN COMMAND DATA BLOCK
• Ensure all reserve fields are set to zero.
• Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
• Verify that the library and its components have the current firmware.
00245
LOGICAL UNIT IS NOT SUPPORTED
• Verify the logical unit field specified in the command contains a legit-
imate logical unit number.
• Check cabling to logical unit.
• Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
• Verify that the library and its components have the current firmware.
00255
INVALID FIELD IN PARAMETER LIST
• Verify Mode Select page fields.
• Verify that fields comply with command format described in this guide.
• Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
• Verify that the library and its components have the current firmware.
00265
HP StorageWorks ESL E-Series Tape Library 131